RadiSys ATCA-4616 Specifications Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 146
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
3
Configuring Shelf Manager and HPI Behavior
37
Disabling the Shelf Manager
Important:WhenthereisonlyoneSCMorShelfManagermoduleintheshelf,disablingits
ShelfManagercausesallshelfmanagementfunctionalitytobelost.Additionally,ifyoupower
cycletheshelforthemodulewiththedisabledShelfManager,allmodulesintheshelf
(includingtheSCMorShelfManagermodule)will beunabletopoweruptheirpayloads.To
reenabletheShelfManagerandallowthepayloadtopowerup,youmustinstalltheSCMor
ShelfManagermoduleintoashelfwithanactiveShelfManagerrunningandthenreenable
it.
1. EstablishaserialconnectiontotheShelfManagermoduleandlogonasroot.Seethe
module’sInstallation Guidefordetails.
2. Atthepromptoftheconnectedcomputer,thefollowingmayappear:
DEBUGMODE:~#
ThisDEBUGMODEpromptisaresultofaconflictbetweentheShelfManageronthemodule
andtheShelfManageronthenonRadisysshelf.DisablingtheShelfManageronthe
moduleresolvesthisconflict.
3. DisabletheShelfManagerbyentering:
rsysipmitoolrsysoemshmcdisable
4. Toverifythatthemodule’sShelfManagerisdisabled,enter:
rsysipmitoolrsysoemshmcinfo
IftheShelfManagerisdisabled,theresponseisShMCstate:Disabled
5. IfasecondSCMisinstalled,performsteps1through4onthesecondSCMaswell.
6. CyclethepowerontheshelftorestartthenonRadisysShelfManager.
7. Seethemodule’sInstallationGuidetocompletetheverificationsteps.