RadiSys EPC-2 Specifications Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 130
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
Troubleshooting & Error Messages
System will not talk
across VMEbus.
The VMEbus backplane
may not be jumpered
correctly.
More than 1 master may
be set to provide Slot-0
functions.
The EPC-7 may have bent
pins.
VMEbus interface failure.
See the section Installing the VXIbus
Backplane Jumpers, on page 7.
Make sure that only 1 system is
configured as the Slot-0 controller
and that it is the left-most system in
the chassis.
Remove the EPC-7 and verify that
no pins are bent. Then reinsert the
EPC-7.
Power off, then back on. Verify that
the results of the power-on self test
indicate VMEbus interface and
VXIbus interface report “ok.”
99
Page 83